NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM123039 Query DataSets for GSM123039
Status Public on Sep 08, 2006
Title MAQC_ABI_2_C5
Sample type RNA
 
Source name MAQC sample C, i.e., MAQC samples A and B mixed at 75%:25% ratio (A:B).
Organism Homo sapiens
Characteristics NA

Extracted molecule total RNA
Label Chemiluminescence - Digoxigenin
Label protocol Digoxigenin-UTP labeled cRNA was generated from 1 µg of total RNA for each MAQC sample (A, B, C, D) using Applied Biosystems NanoAmp RT-IVT Labeling Kit (P/N 4365715) according to the manufacturer’s protocol.
 
Hybridization protocol Array hybridization, array processing, chemiluminescence detection, image acquisition, and analysis were performed using Applied Biosystems Chemiluminescence Detection Kit and Applied Biosystems 1700 Chemiluminescent Microarray Analyzer following manufacturer’s protocol.
Scan protocol Chemiluminescent Detection Kit (P/N 4339627, http://docs.appliedbiosystems.com/pebiodocs/04339627.pdf) and Chemiluminescent Microarray Analyzer User Guide (P/N 4338852B).
Description NA
Data processing The Expression Array System Software suite performs the auto-gridding, feature extraction, fluorescence normalization, and signal data generation. The quantification data contain many distinct measurements for each probe, including the three basic measurements: Signal, S/N, and Flag values. The Signal value is the fully corrected, background subtracted measurement of chemiluminescent signal for gene expression values. The S/N value represents the ratio of signal above noise, or the measurement uncertainty of the probe signal, and can be used as a confidence level for the probe measurement. An S/N of 3 represents approximately a 99.95% confidence that the probe is detected above the background noise. In situations where the probe showed S/N < 1, the signal measurement is replaced with a 1 SDEV upper limit based on its probe signal SDEV.
 
Submission date Jul 24, 2006
Last update date Aug 17, 2006
Contact name Leming Shi
E-mail(s) lemingshi@fudan.edu.cn
Phone +86-18616827008
Organization name Fudan University
Department School of Life Sciences
Lab Center for Pharmacogenomics
Street address 2005 Songhu Road
City Shanghai
ZIP/Postal code 200438
Country China
 
Platform ID GPL2986
Series (1)
GSE5350 MicroArray Quality Control (MAQC) Project

Data table header descriptions
ID_REF Manufacturer's probe ID
VALUE The signal value is the fully corrected, background subtracted measurement of chemiluminescent signal for gene expression values. Data were quantile-normalized per test site (20 arrays).
Flag_Detection An S/N of 3 represents approximately a 99.95% confidence that the probe is detected above the background noise.

Data table
ID_REF VALUE Flag_Detection
100002 147329.75 76.14
100003 227.413 -0.26
100027 269.564 0.75
100036 10959 33.9
100037 38011.887 38.34
100039 7457.573 25.39
100044 999.83 3.89
100045 879.79 -0.34
100051 177.77 -0.78
100052 1491.091 5.78
100057 2793.409 7.27
100058 55107.688 47.28
100060 267.75 -0.25
100062 776.993 0.48
100064 2533.157 13.74
100079 182082.938 47.51
100089 9497.079 20.3
100093 11424.561 35.2
100095 717.027 -0.28
100100 31291.156 59.16

Total number of rows: 32878

Table truncated, full table size 681 Kbytes.




Supplementary file Size Download File type/resource
GSM123039_ABI_2_C5.txt.gz 284.3 Kb (ftp)(http) TXT

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap